Recirculation with On-Demand Accessories User Guide
Related Manuals for Rinnai Control-R
Summary of Contents for Rinnai Control-R
- Folio i ENGLISH Recirculation with On-Demand Accessories User Guide...
-
Page ii: Installation Tips
This manual provides detailed information on Rinnai's on-need recirculation accessories; it is designed for field installers and is a supplement to the Control-R™ Wi-Fi Module Installation Manual (supplied inside module package). one What is Recirculation? ........3 Recirculation Components ........3 Tankless Water Heaters with Circ-Logic .... - Folio three Circ-Logic is Rinnai's recirculation engineering science built into Rinnai Tankless H2o Heaters. Circ-Logic defines recirculation patterns that coincide with your hot water usage. Hot water is available when and where you desire it with the on-need recirculation components listed beneath. Once connected and the Rinnai app is downloaded, the Rinnai Tankless Water Heater tin can exist controlled from the user'south smart phone or tablet.
- Page four Models with Recirculation Adequacy With Without Internal Pump Internal Pump Circ-Logic is included in Rinnai's The post-obit models include Circ- SE+ Series featuring Therma- Logic, just require installation of Circ360™ models (Super Loftier an external recirculation pump Efficiency Plus RUR Models): (purchased separately): •...
- Page 5 The on-demand accessory is activated (push button is pressed, motion sensor activated, etc.) A request (non a control) is sent to the water heater to turn on the pump. In other words, the push button or movement sensor is asking the water heater if the pump can plow on to get-go recirculation.
- Page 6 Recirculation with On-Need Accessories User Guide...
- Folio vii Will NOT turn dorsum on. The ON betoken is all the same sent to the water heater for a 5-minute timer. If the dormant menses completes with time available on the Control-R™ timer, the pump volition activate for those remaining minutes (see example below).
- Page viii • Non-RUR models that are equipped with Circ-Logic crave installation of an external recirculation pump RUR Models (Include Internal Recirculation Pump) Typical Pump OFF Intervals (Minutes) Rinnai Temperature Setting °F Economy Way Comfort Mode Recirculation with On-Demand Accessories User Guide...
- Page 9 Temperature Economy Comfort Comfort mode is recommended with on-demand recirculation accessories as information technology cycles the pump more than frequently, ensuring the loop temperature remains higher. • The push button or motion sensor is activated. • If the h2o heater accepts the request, the pump runs for v minutes (or until the water temperature is reached) and then turns off.
- Page x Not-RUR Models (External Recirculation Pump Required) Typical Pump OFF Intervals (Minutes) Rinnai Temperature Setting °F Economic system Mode Condolement Mode Recirculation with On-Demand Accessories User Guide...
- Page 11 The tabular array beneath illustrates pump OFF intervals for units using a crossover valve. Of import The internal pump in an RUR model runs based on time intervals only and not water temperature (like dedicated return line recirculation systems). Typical Intervals Pump Status Long Loop Manner Short Loop Style (201—400 Ft)
- Page 12 Appendix B → Recirculation Settings department. Y'all will need: • On-Demand Accompaniment and Batteries (supplied with purchase) • Control-R™ Wi-Fi Module • Phillips Head Screwdriver (field-supplied) Boosted Items Required for SENSEI™ Water Heaters: • Water Heater Controller Cable (included in h2o heater packaging) •...
- Page thirteen Connect Module: 1. Unplug water heater ability cord from power outlet. two. Remove h2o heater forepart panel (apply a Phillips Head screwdriver to remove 4 screws securing the panel). 3. Connect module wires to PC Board located inside water heater by completing steps a, b, and c below.
- Folio 14 c. Connect controller cable to PC Board through grommet portal on bottom, correct side of h2o heater. Insert controller cable through grommet portal Connect cable to PC Lath 4. Plug h2o heater power cord into a power outlet. Recirculation with On-Need Accessories User Guide...
- Folio 15 Pair Accessory to Module: 5. Wait for module LED to turn RED. While you are waiting, go on with next stride. six. Insert accessory batteries by following the steps below: Push Button Batteries • Printing both sides. And then, elevator and remove cover.
- Page xvi Move Sensor/Temperature Sensor Batteries • Apply a Phillips Head screwdriver to remove the front end cover. • Insert the supplied battery while pressing downwards on the accessory Connect push at the same time. Battery type is 2600mAh AA size Lithium-Thionyl Chloride battery (three.6V or 3.7V).
- Page 17 eight. You have v minutes to consummate the bullets beneath: Push button Push: • Press and hold down push push button. • Push button flashes iii times so rapidly flashes. • Release push button. Motion Sensor and Temperature Sensor: • Printing and hold the Connect button on the accessory until the accompaniment LED quickly flashes.
- Folio 18 10. Activate on-demand accessory (press push button button, activate movement sensor, etc.). Module LED quickly blinks Greenish and turns RED. (This signifies communication between on-demand accessory and module.) Important: After activating on-demand accessory (pressing push, activating movement sensor, etc.), DO Non activate it over again until five-minute timer is complete (as explained in next step).
- Page 19 Configure Water Heater Settings to Comfort Mode: 12. Press On/Off button on controller to turn OFF water heater. IMPORTANT: Controller MUST be turned OFF for remaining steps to work correctly. 13. Press and hold down A button on PC Board for i second. The controller turns ON.
- Page 20 15. Press On/Off button until appears in display. 16. Printing Up arrow until 0 5 A appears in brandish. 17. Press On/Off push button until appears in display. 18. Condolement mode is selected. To select boosted parameters, see Appendix B. When parameter settings are consummate, press and hold downwards A button on PC Board for one second to exit parameters.
- Page 21 xix. Replace water heater front panel. COMPLETE REMAINING STEPS ONLY AFTER 5-MINUTE TIMER IS FINISHED FROM Stride 11 ON PAGE 18. twenty. Press On/Off button on water heater controller to turn ON water heater. 21. Actuate the on-demand accompaniment (press push button, activate movement sensor, etc.) Module LED blinks GREEN and pump turns on.
- Page 22 22. Instructions for pairing 1 on-demand accessory are complete. To pair boosted accessories, follow the steps beneath. Pair Additional On-Demand Accessories • Press On/Off push on water heater controller to turn OFF h2o heater. • Unplug water heater power cord from outlet and and then plug information technology dorsum in.
- Page 23 Connect Module: 1. Unplug the water heater power string from power outlet. 2. Remove water heater front end panel (utilize a Phillips Head screwdriver to remove 4 screws securing the panel). 3. Place the 2 module wires through the lesser opening of the water heater.
- Page 24 Pair Accessory to Module: half dozen. Wait for module LED to turn Crimson. While y'all are waiting, proceed with side by side step. 7. Insert accompaniment batteries by following the steps below: Push Batteries • Printing both sides. And then, elevator and remove cover.
- Page 25 Motion Sensor/Temperature Sensor Batteries • Utilise a Phillips Head screwdriver to remove the front end cover. • Insert the supplied battery while pressing downwardly on the accessory Connect push at the aforementioned time. Battery blazon is 2600mAh AA size Lithium-Thionyl Chloride battery (3.6V or iii.7V).
- Page 26 9. You have five minutes to consummate the following steps: Push button: • Press and concord down push. • Button push button flashes three times and then speedily flashes. • Release push button. Motion Sensor and Temperature Sensor — Press and agree the Connect button on the accessory until the ac- cessory LED quickly flashes.
- Page 27 11. Actuate on-demand accompaniment (printing push button, activate movement sensor, etc.). Module LED quickly blinks GREEN and turns Carmine. (This signifies communication between on-demand accessory and module.) IMPORTANT: Afterward activating on-demand accessory (pressing push button, activating motion sensor, etc.), DO Non activate it again until 5-minute timer is complete (every bit explained in next step).
- Page 28 Configure Water Heater Settings to Comfort Mode: xiii. Press On/Off button on controller to turn OFF water heater. Of import: Controller MUST exist turned OFF for remaining steps to work correctly. 14. On the PC board, suit switches #iv and #8 in the second (or lower) group of switches (DIPSW 2) to ON.
- Page 29 COMPLETE REMAINING STEPS ONLY AFTER 5-Minute TIMER IS FINISHED FROM STEP 12 ON Page 27. 16. Press On/Off button on water heater controller to plow ON water heater. 17. Activate the on-demand accessory (press push button, activate motion sensor, etc.) Module LED blinks GREEN and pump turns on.
- Folio 30 18. Instructions for pairing 1 on-need accompaniment are complete. To pair additional accessories, follow the steps below. Pair Additional On-Demand Accessories • Press On/Off button on water heater controller to plow OFF water heater. • Unplug h2o heater power string from outlet then plug it back in.
- Folio 31 6. Circ-Logic is now reset. 7. You tin can press a button, trigger a movement sensor, or apply the Rinnai app to start the recirculation pump. 8. If more than testing is needed, repeat steps 1-5. Recirculation with On-Demand Accessories User Guide...
- Page 32 Check out the latest tips and tricks for a successful, stress-complimentary installation. • Additional wiring can run up to 300 feet (91 m) away from water heater (eighteen-22 gauge wire required). • Running cold h2o through the recirculation line will not strength the pump to turn on.
- Page 33 Q: How many push buttons and motion sensors are supported per each module? Upward to 30 on-demand recirculation accessories are supported per module. There is no limit per the blazon of accessory as long as the total number of accessories do not exceed xxx. Q: Is the homeowner's wi-fi necessary for recirculation with on- demand accessories? No.
- Page 34 Q: Can I disable Circ-Logic and plough on the recirculation pump with no restrictions? No. Circ-Logic keeps the pump from running when it does not need to. Placing the water heater in Comfort mode will lessen the wait time between pump cycles. If the pump does not plow on, the water in the pipes should already be warm;...
- Page 35 When trying to connect or disconnect power to the tankless water heater, Rinnai recommends using the water heater ability plug instead of using the Reset feature on the module.
- Page 36 Guidelines: • The module must be installed indoors (including outdoor water heaters). • Mount the module to a wall or side of h2o heater (with the use of a magnetic backing). This option is for indoor water heaters merely. Place the magnetic back side of the module to the side of the water heater.
- Page 37 Use a level to ensure the slots are fifty-fifty. ❷ Use a ability drill to drill pilot holes for the module screws and anchors. ❸ Insert the 2 wall anchors (supplied) into each pigsty until they sit down flush against the wall. ❹...
- Page 38 Parameter settings tin be set with the water heater turned OFF. Of import Refer to "Rinnai Tankless Water Heater Installation and Functioning Transmission" for complete list of water heater parameter settings. i. Press On/Off button on controller to turn OFF water heater.
- Page 39 ane. Printing On/Off push on controller to plough OFF water heater. 2. Press A button on PC Board for 1 2d. 3. Printing Upwards arrow until appears in display. 4. Press On/Off push button until the post-obit appears in display: • No Recirculation •...
- Page 40 100000631(1) xi/2018 Recirculation with On-Demand Accessories User Guide...